Manufacturer technical reference describing position-synchronised process triggering. PSO means Position Synchronized Output in this motion-control context. Its purpose is to relate laser or process events to movement rather than assume that fixed time intervals always create fixed spatial spacing.
Controller architecture, kinematic transformations and the source of position information affect implementation. Retain the stated system configuration when using this reference for a scanner or multi-axis motion project.